WI-35 WORK INSTRUCTION FOR MAGNAFLUX CRACK DETECTION

Doc. No:  KKM/GWI/35 WORK INSTRUCTION FOR MAGNAFLUX CRACK DETECTION
Rev.  No.:  01
Rev. Date:   20.11.2012
  • Power on the machine & check the fluid for proper flow. Give 10 minutes for proper agitation.
  • Power on the ultra-violet lamp.(Min- for 5 Minutes) before start of inspection process.
  • Visually check the 100% parts for scale, rust, oil etc. before MPI.
  • Set the machine for direction of magnetisation (longitudinal/combined) as per the requirement.
  • Set the current between 1200-1900 amps. Or as required level.
  • Clean the standard test piece & jobs thoroughly by washing in kerosene oil/fluid.
  • Clean the job and put ASTM test piece on the job.
  • Start magnetization (Increase or decrease the current till the defect is clearly visible).
  • Spray the job with Carrier Oil & magnetic powder mixture & apply current as soon as the spray is stopped.
  • Inspect under ultraviolet light. (The defect will be visible as fluorescent line streak or as the defect morphology).
  • Change the current until cracks on ASTM test piece are visible.
  • Remove ASTM test piece.
  • Apply current and see the jobs for surface defects. (The defect will be visible as fluorescent line streak or as the defect morphology).
  • Demangnitize the jobs after inspection & check the residual magnitisation with residual field indicator.

Precautions/ सावधानियां:

  •  Remove wrist watch before using the machine.
  • Apply Kerodex cream on hands & exposed skin before starting the machine.
  • Clamp the jobs tight. Replace copper pads if worn out otherwise electric sparking during current flow may start fire.
  • In case of fire, power down the machine immediately and raise alarm.